thermocouple stranded twisted wire type K NiCr NiAl

 

Thermocouple temperature range and tolerance

 

Type Standard Operating temperature range (°C) Tolerance(°C)
Long term Short term Grade Temperature range Tolerance
Type K GB/T2614 K 1200 1300 I -40~1100 ±1.5°C/±0.4%t
II -40~1300 ±2.5°C/±0.75%t
Type N GB/T17615 N 1200 1300 I -40~1100 ±1.5°C/±0.4%t
II -40~1300 ±2.5°C/±0.75%t
Type E GB/T4993 E 750 900 I -40~800 ±1.5°C/±0.4%t
II -40~900 ±2.5°C/±0.75%t
Type J GB/T4994 J 600 750 I 0~750 ±1.5°C/±0.4%t
II ±2.5°C/±0.75%t
Type T GB/T2903 T 300 350 I -40~350 ±0.5°C/±0.4%t
II ±1°C/±0.75%t
III -200~40 ±1°C/±1.5%t
 

 

 

MAIN CHARACTERISTICS OF WISDOM THERMOCOUPLE ALLOYS

 

TYPE J (Iron vs Constantan) is used in vacuum, oxidizing, inert or reducing atmospheres. Iron element oxidizes rapidly at temperatures exceeding 538'C, and therefore heavier gauge wire is recommended for longer life at these temperatures. 

TYPE K (CHROMEL vs ALUMEL ) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures. 

TYPE T (Copper vs Constantan) is used or service in oxidizing, inert or reducing atmospheres or in vacuum. It is highly resistant to corrosion from atmospheric moisture and condensation and exhibits high stability at low temperatures. It is the only type with limits of error guaranteed for cryogenic temperatures.

TYPE E (CHROMEL vs Constantan) may be used in oxidizing, inert or dry reducing atmospheres, or for short periods of time under vacuum. Must be protected from sulfurous and marginally oxidizingatmospheres. Produces the highest EMF per degree o any standardized thermocouple.

 

Type N thermocouple (Ni Cr Si-Ni Si Mg)  is the latest base metal thermocouple, developed to improve the drawbacks that type K thermocouple has. The main chemical composition of positive leg Nicrosil(NP) is Ni: Cr: Si≈84.4: 14.2: 1.4; negative leg Nisil (NN) is Ni: Si: Mg≈95.5: 4.4: 0.1. Type N thermocouple also be used in the similar atmospheres that type K works, and the operating temperature range is -200~1300 °C.